MU02

Representative, low-energy and lownoise cell constructed in accordance with HACCP & GMP requirements, with a volume of 71 m³. Especially developed for ultra-low temperatures down to minus 45 °C with a complete back-up cooling system. Ready for use and easy to install with a crane truck, even in locations that are difficult to reach. Can be used both outdoors and indoors. Uses ozone-friendly cooling agent. Accessible via door that can also be opened from the inside. Including lighting and door frame heating.
MU02

Downloads

Productsheet Downloads

Technical specifications

Amount of pallets (euro) 24
Volume 71 m³
Min. inside temperature -45 °C
Max. inside temperature -20 °C
Min. outside temperature -20 °C
Power connection 2 x 63 A CEE
Voltage 400 V
Current (max) 41.8 A
Current (nominal) 28.2 A
Recommended fuses 2 x 63 A
Phases 3 + N + PE
Length (external) 12000 mm
Width (external) 3500 mm
Height (external) 3000 mm
Length (internal) 8900 mm
Width (internal) 3140 mm
Height (internal) 2520 mm
Door height 2100 mm
Door width 1400 mm
Threshold height 290 mm
Max. load 1200 Kg/m²
Weight 9500 kg
Sound level (at 10 m) 61 dB(A)